Supplying you with customized nhxmh/(n)hxmh(st), it is one of the reliable nhxmh/(n)hxmh(st) manufacturers and suppliers, welcome to wholesale our products at good price from our factory.
German Standard Industrial Cables NHXMH/(N)HXMH(St)
Application and Description
|
NHXMH cable is halogen free intended for fixed installation in dry and moist rooms as well as in masonry and concrete, in and under plaster; not for underground installation. NHXMH-J/O are especially used in buildings witd a high concentration of persons or valuable property, where improved fire characteristics are needed. This product conforms to 73/23/EW G directive (low voltage directive) CE.
|
Standard and Approval
|
VDE 0250 (part 214), VDE 0482 (part 266-2-4, test type C), IEC 60228; IEC 60332-3-22; IEC 60754-1; IEC 60754-2, IEC 61034
|
Cable Construction
|
- Plain copper conductor, single conductor up to 10 mm² multi-conductor from 16-35 mm² - To DIN VDE 0295 cl. 1 or 2, BS 6360 cl. 1 or 2 and IEC 60228 cl. 1 or 2 - Cross-linked polyetdylene compound insulation 2XI1 to DIN VDE 0207 part 22 - Color coded to DIN VDE 0293-308 - Green-yellow grounding (3 conductors and above) - Halogen free filling compound (not for single core cables) - Flame-retardant, halogen free polyetdylene compound jacket HM2 according to DIN VDE 0207 part 2
|
Technical Characteristics
|
- Working voltage: 300/500 volts - Test voltage: 2000 volts - Minimum bending radius: single conductor 15 x Ø - Minimum bending radius: multi conductor 12 x Ø - Flexing temperature: -5º C to +50º C - Fixed installation temperature: - 30º C to +70º C - Short circuit temperature: +250º C - Flame-retardant to DIN VDE 0482 part 266-2/HD 405.3/BS 4066 PT3/EN 50266-2/IEC 60332-3 - Low corrosiveness of combustion gases to DIN VDE 0482 part 267/BS 6425 PT2/EN 50267-2-2/IEC 60754-2 - Halogen-free to DIN VDE 0482 part 267/BS 6425 PT1/EN 50267-2-1/IEC 60754-1 - Smoke density to DIN VDE 0482 part 268/HD 606/BS 7622 PT1,PT2/EN 50268-1,-2/IEC 61034-1,-2 - Insulation resistance: 100 MΩ x km
|
Cable Parameter
AWG
|
NO. OF CORES X
NOMINAL CROSS
SECTIONAL AREA
# X MM²
|
STRANDED CONDUCTOR TYPE
|
NOMINAL
OVERALL DIAMETER MM
|
NOMINAL COPPER WEIGHT KG/KM
|
NOMINAL CABLE WEIGHT KG/KM
|
16
|
1 x 1.5
|
re
|
7
|
15
|
49
|
14
|
1 x 2.5
|
re
|
7.6
|
24
|
60
|
12
|
1 x 4.0
|
re
|
8.6
|
39
|
80
|
10
|
1 x 6.0
|
re
|
9.9
|
58
|
111
|
8
|
1 x 10.0
|
re
|
11.2
|
96
|
160
|
6
|
1 x 16.0
|
re
|
11.9
|
154
|
232
|
16
|
2 x 1.5
|
re
|
8.9
|
29
|
110
|
14
|
2 x 2.5
|
re
|
10
|
48
|
136
|
12
|
2 x 4.0
|
re
|
11.4
|
77
|
202
|
16
|
3 x 1.5
|
re
|
9.4
|
43
|
130
|
14
|
3 x 2.5
|
re
|
10.4
|
72
|
163
|
12
|
3 x 4.0
|
re
|
11.8
|
115
|
235
|
10
|
3 x 6.0
|
re
|
13.4
|
173
|
323
|
8
|
3 x 10.0
|
re
|
16
|
288
|
485
|
6
|
3 x 16.0
|
re
|
19.7
|
461
|
850
|
4
|
3 x 25.0
|
rm
|
24.3
|
720
|
1152
|
2
|
3 x 35.0
|
sm
|
27.2
|
1008
|
1503
|
16
|
4 x 1.5
|
re
|
10.2
|
58
|
151
|
14
|
4 x 2.5
|
re
|
11.3
|
96
|
200
|
12
|
4 x 4.0
|
re
|
13.3
|
154
|
300
|
10
|
4 x 6.0
|
re
|
14.8
|
230
|
400
|
8
|
4 x 10.0
|
re
|
17.4
|
384
|
603
|
6
|
4 x 16.0
|
re
|
21.6
|
615
|
940
|
4
|
4 x 25.0
|
rm
|
27
|
960
|
1432
|
2
|
4 x 35.0
|
sm
|
29.9
|
1344
|
1930
|
16
|
5 x 1.5
|
re
|
10.8
|
72
|
177
|
14
|
5 x 2.5
|
re
|
11.9
|
120
|
238
|
12
|
5 x 4.0
|
re
|
14.8
|
192
|
345
|
10
|
5 x 6.0
|
re
|
16
|
288
|
475
|
8
|
5 x 10.0
|
re
|
18.9
|
480
|
720
|
6
|
5 x 16.0
|
|